Automatic Transfer Switch HiSmart W2R-3P 220V 100APV box

Automatic Transfer Switch HiSmart W2R-3P 220V 100A

Product code: HS082499EAN13 barcode: 9990001082499
Automatic transfer switch HiSmart W2R-3P 220V 100A


Features:
Automatic transfer switch 220VAC, 100A for emergency power supply system 50/60Hz, transfer time <50ms.
The switch can also be operated manually.
The switch complies requirements of low voltage switch gear and control gear specified by IEC 60947-6-1, IEC 60947-3.
Compact design, reliable switching, easy installation on a DIN rail.
It is widely applicable in various occasions where continuous power failure is not allowed.


Specifications:
Voltage: AC220V.
Current: 100A.
Frequency: 50/60Hz.
Number of contacts: 3.
Insulation voltage (Ui): AC 690V.
Rated voltage (Ue): AC 400V.
Rated conditional short-circuit current: 50 kA.
SCPD (fuse): RT16-00-63A.
Rated impulse withstand voltage: 8 kV.
Main voltage: AC 220V.
Auxiliary circuit: AC 220V.
Contact transfer time: <50 ms.
Operating transfer time: <50ms.
Return transfer time: <50ms.
Off- time: <50ms.
Installation: on a DIN rail.
Dimensions: 125x95x80 mm.
Mechanical life: 5000 times.
Electrical life: 2000 times.
Operating temperature: -5°C ~ +40°C (24-hour average temperature should not be more than 35°C).
Weight: 633g.


Warranty: 24 months.


Download Manual
64.83 €Price (with VAT) Buy
In stock
  • Technical specifications
Automatic transfer switch HiSmart W2R-3P 220V 100A


Features:
Automatic transfer switch 220VAC, 100A for emergency power supply system 50/60Hz, transfer time <50ms.
The switch can also be operated manually.
The switch complies requirements of low voltage switch gear and control gear specified by IEC 60947-6-1, IEC 60947-3.
Compact design, reliable switching, easy installation on a DIN rail.
It is widely applicable in various occasions where continuous power failure is not allowed.


Specifications:
Voltage: AC220V.
Current: 100A.
Frequency: 50/60Hz.
Number of contacts: 3.
Insulation voltage (Ui): AC 690V.
Rated voltage (Ue): AC 400V.
Rated conditional short-circuit current: 50 kA.
SCPD (fuse): RT16-00-63A.
Rated impulse withstand voltage: 8 kV.
Main voltage: AC 220V.
Auxiliary circuit: AC 220V.
Contact transfer time: <50 ms.
Operating transfer time: <50ms.
Return transfer time: <50ms.
Off- time: <50ms.
Installation: on a DIN rail.
Dimensions: 125x95x80 mm.
Mechanical life: 5000 times.
Electrical life: 2000 times.
Operating temperature: -5°C ~ +40°C (24-hour average temperature should not be more than 35°C).
Weight: 633g.


Warranty: 24 months.


Download Manual