Automatic Transfer Switch HiSmart W2R-2P 220V 100APV box

Automatic Transfer Switch HiSmart W2R-2P 220V 100A

Код продукта: HS082482EAN13 штрих-код: 9990001082482
Automatic transfer switch HiSmart W2R-2P 220V 100A




Features:

Automatic transfer switch 220VAC, 100A for emergency power supply system 50/60Hz, transfer time <50ms.

The switch can also be operated manually.

The switch complies requirements of low voltage switch gear and control gear specified by IEC 60947-6-1, IEC 60947-3.

Compact design, reliable switching, easy installation on a DIN rail.

It is widely applicable in various occasions where continuous power failure is not allowed.




Specifications:

Voltage: AC220V.

Current: 100A.

Frequency: 50/60Hz.

Number of contacts: 2.

Insulation voltage (Ui): AC 690V.

Rated voltage (Ue): AC 400V.

Rated conditional short-circuit current: 50 kA.

SCPD (fuse): RT16-00-63A.

Rated impulse withstand voltage: 8 kV.

Main voltage: AC 220V.

Auxiliary circuit: AC 220V.

Contact transfer time: <50 ms.

Operating transfer time: <50ms.

Return transfer time: <50ms.

Off- time: <50ms.

Installation: on a DIN rail.

Dimensions: 100x105x70 mm.

Mechanical life: 5000 times.

Electrical life: 2000 times.

Operating temperature: -5°C ~ +40°C (24-hour average temperature should not be more than 35°C).

Weight: 527g.




Warranty: 24 months.




Download Manual

60.21 €Цена (с НДС) Купить
Eсть на складе
  • Технические характеристики
Automatic transfer switch HiSmart W2R-2P 220V 100A




Features:

Automatic transfer switch 220VAC, 100A for emergency power supply system 50/60Hz, transfer time <50ms.

The switch can also be operated manually.

The switch complies requirements of low voltage switch gear and control gear specified by IEC 60947-6-1, IEC 60947-3.

Compact design, reliable switching, easy installation on a DIN rail.

It is widely applicable in various occasions where continuous power failure is not allowed.




Specifications:

Voltage: AC220V.

Current: 100A.

Frequency: 50/60Hz.

Number of contacts: 2.

Insulation voltage (Ui): AC 690V.

Rated voltage (Ue): AC 400V.

Rated conditional short-circuit current: 50 kA.

SCPD (fuse): RT16-00-63A.

Rated impulse withstand voltage: 8 kV.

Main voltage: AC 220V.

Auxiliary circuit: AC 220V.

Contact transfer time: <50 ms.

Operating transfer time: <50ms.

Return transfer time: <50ms.

Off- time: <50ms.

Installation: on a DIN rail.

Dimensions: 100x105x70 mm.

Mechanical life: 5000 times.

Electrical life: 2000 times.

Operating temperature: -5°C ~ +40°C (24-hour average temperature should not be more than 35°C).

Weight: 527g.




Warranty: 24 months.